Product Details:
Minimum Order Quantity | 5 Piece |
Power Source | Build in NiCd Battery |
Brand | Placom |
Application | Industrial, Laboratory, Geographical |
Model | KP 90N, Placom KP90N |
Accessories | Supplied AC Adaptor and Plastic Case |
Accuracy | within +/- 0.2% |
Battery Charging Time | approx 15hr. |
Measuring Range | Maximum vertical width : 325mm |
Symbol | 8 Digit Figure and 13 Symbols |
Type | Roller Type with Computing Function |
Weight | 750g |
The most standard model of “Koizuimi Placom” N-Series has made the excitingly highest attainment in the history of Placom Digital Planimeter KP-90N ever made. Measuring capacity is remarkably enlarged. Measuring by 6-digit pulse count enables to measure 100 times larger accumulative area than ordinary planimeters. Easy calculations of Cumulative and Average Value Measurement.
Applications:
Measurement by 6 digit pulse count
This N-Series can measure the area by pulse count of 6-digits. This method enables a larger cumulative measurement of area (Up to 10m²)
Maximum cumulative measurement value of 10m²
With the measurement by 6-digit pulse count, the N-Series Planimeter can measure a larger area by 100 times than ordinary Planimeter.
The conventional planimeter has a maximum cumulative area to measure only 0.1m². If measurement value shows over 0.1m2 when measuring, the display is to be reset to “O”.
This requires to register the numbers of how many times these re-settings are occurred.
With the New PLACOM N-Series, there is no need of these troublesome procedures.
Easy conversion function of unit and scale
Placom KP-90N can convert easily the measured area value into a new area value in a newly desired unit and with a newly desired scale value.
Placom KP-92N and KP-82N can convert the unit between in² and cm²
Hold memory function
In cumulative measurement, this Hold Memory function is effectively used. If an error occurs in measuring, press C/AC key. Then last measured value is appeared by pulse count. Since previous measured values before error are stored, there is no need to another measurements from the beginning.
Automatic shifting of unit to upper unit
When the measured area value overflows the displayed figures of 8 digits, the measured area value is calculated and displayed by an upper unit. When the overflows is occurred in the uppermost unit, km², acre, the measurement can be continued by pulse count display.
Average value measurement
In order to get better result of measurement, Mean value measurement is recommended. This measurement can be easily done on this N-Series.